WALDESKI
Fire and Steel Doors
The development of modern technology today, both buildings and factories require high quality security to protect against fire hazards. One of the important equipment is Fire Door or commonly called the building's door emergency exit. Where every building is required to have a building emergency exit or fire emergency door.​ Fire doors have a dual function, apart from preventing the spread of fire from one room to another, they are also an important means of human safety, especially as fire emergency exits in public buildings.​
With so many requests for Fire Door doors then Waldeski is ready to serve a wide variety of iron & steel doors for fire doors, steel doors, building emergency doors with the best quality to meet various architectural needs.
This fire door is designed with fire-resistant materials where the frames and doors are formed from quality steel plates and processed with a rockwool fire-resistant coating. and the desired specifications, and we are ready to help for your door product solutions.
Thermal Insulation
The ability to insulate the door against the spread of heat is absolutely necessary, if the door is used for human entry and exit. The ability of this room dividing element is needed in building construction to prevent heat from spreading. Fire Rating The time of protection against fire does not have to be the same for all parts of the building, depending on how long the door must resist fire for the time needed.
Integrity Against Fire
The ability of a room dividing element in a building when it is burning on one side, to prevent gaps so that flames and hot smoke cannot penetrate or cause flames on the non-burning side
Stability Against Fire
The ability of structural members of buildings with or without bearings to withstand collapse in the event of a fire
Single Fire Door
The door leaf uses a 24mm wide lip. The door leaf is filled with 100kg/m3 Rockwool with a frame plate thickness of 2 mm and a door leaf plate thickness of 1.5 mm and a door leaf thickness of 55 mm
Single Fire Door with Glass
The door leaf uses a 24 mm wide lip. The door leaf is filled with 100 kg/m3 Rockwool with a frame plate thickness of 2 mm and a door leaf plate thickness of 1.5 mm and a door leaf thickness of 55 mm listen 5 mm thick plain glass
Double Fire Doors
The door leaf uses a 24 mm wide lip. The door leaf is filled with 100 kg/m3 Rockwool with a frame plate thickness of 2 mm and a door leaf plate thickness of 1.5 mm and a door leaf thickness of 55 mm listen 5 mm thick plain glass